Nick O'Leary
faa7d948a7
Update MQTT Out node status if already connected
2015-04-27 20:08:00 +01:00
dceejay
105d38c885
MQTT node - don't report missing topic if payload is missing...
2015-04-14 18:39:42 +01:00
dceejay
d7bdcd69fc
fix exec missing addpayload,
...
improve switch null test (to include null object)
check mqtt has payload before sending
2015-04-14 17:15:56 +01:00
Nick O'Leary
f48ee01a03
Ensure MQTT nodes unsubscribe before disconnect
...
Fixes #609
Needed for partial deployment - the nodes assumed the
connection would always be closed when a deploy occurs.
2015-04-09 20:10:34 +01:00
dceejay
2a47951e46
make sure MQTT msg has a topic
2015-03-16 17:07:46 +00:00
Dave C-J
273acc0ec4
Let MQTT input node receive binary packets
...
Try to auto select output type to be string or buffer to be backwards compatible
Fixes #435
2014-11-04 21:56:15 +00:00
Mark Hindess
5d9c16ffbf
Remove redundant msg != null checks.
2014-09-08 21:10:06 +01:00
Dave C-J
cba4791b65
MQTT node better check for topic existing
2014-09-08 20:19:25 +01:00
Dave C-J
ab4d3c025e
MQTT node should only send message if topic actually specified (string)
2014-09-08 20:01:28 +01:00
Dave C-J
a8ade083d4
Add QoS and Retain to the MQtt node options
2014-08-22 12:44:54 +01:00
Dave C-J
0b308deb79
Slight tidy to MQTT - move to fa icons - use built in close method.
2014-07-21 20:29:10 +01:00
Nick O'Leary
760dd022dc
Migrate MQTT nodes to new credentials api
2014-07-19 00:25:22 +01:00
Mark Hindess
5073cf8dd7
Reduce scope of variable declaration to be consistent with MQTTInNode code.
2014-07-16 21:45:02 +01:00
Mark Hindess
77f6652fa9
Remove spurious variable declaration.
2014-07-16 21:45:02 +01:00
Nick O'Leary
70147d0b6b
Remove 'retined' property from node.status calls
2014-05-30 20:30:26 +01:00
Dave C-J
7ad28de52a
Add use strict to mqtt node, allow will parm to be passed.
2014-05-29 09:00:28 +01:00
Nick O'Leary
7e85eb297d
Make status display toggleable and add to MQTT nodes
2014-05-10 23:33:02 +01:00
Nick O'Leary
ff49d2b217
Migrate to new node function style
2014-05-03 23:32:04 +01:00
Nick O'Leary
7c24d4d760
Separate out httpAdmin and httpNode
2014-02-16 00:39:30 +00:00
Nicholas O'Leary
7040aaa179
Add clientid/username/password to MQTT nodes
...
Alternative implementation, closes #42
The username/password as not stored in the main flow file for security reasons;
they are stored in the adjacent credentials file. This does mean an extra step
to importing an MQTT node, as the user has to manually edit it to re-add username
and password if needed.
2013-11-25 22:50:08 +00:00
Nicholas O'Leary
48dabffefc
Move all nodes into core subdirectory
...
This makes it easier to distinguish core nodes from those added later
2013-11-14 15:52:19 +00:00