133 lines
3.6 KiB
C
133 lines
3.6 KiB
C
|
/*
|
||
|
* PCI support for Xilinx plbv46_pci soft-core which can be used on
|
||
|
* Xilinx Virtex ML410 / ML510 boards.
|
||
|
*
|
||
|
* Copyright 2009 Roderick Colenbrander
|
||
|
* Copyright 2009 Secret Lab Technologies Ltd.
|
||
|
*
|
||
|
* The pci bridge fixup code was copied from ppc4xx_pci.c and was written
|
||
|
* by Benjamin Herrenschmidt.
|
||
|
* Copyright 2007 Ben. Herrenschmidt <benh@kernel.crashing.org>, IBM Corp.
|
||
|
*
|
||
|
* This file is licensed under the terms of the GNU General Public License
|
||
|
* version 2. This program is licensed "as is" without any warranty of any
|
||
|
* kind, whether express or implied.
|
||
|
*/
|
||
|
|
||
|
#include <linux/ioport.h>
|
||
|
#include <linux/of.h>
|
||
|
#include <linux/pci.h>
|
||
|
#include <mm/mmu_decl.h>
|
||
|
#include <asm/io.h>
|
||
|
#include <asm/xilinx_pci.h>
|
||
|
|
||
|
#define XPLB_PCI_ADDR 0x10c
|
||
|
#define XPLB_PCI_DATA 0x110
|
||
|
#define XPLB_PCI_BUS 0x114
|
||
|
|
||
|
#define PCI_HOST_ENABLE_CMD PCI_COMMAND_SERR | PCI_COMMAND_PARITY | PCI_COMMAND_MASTER | PCI_COMMAND_MEMORY
|
||
|
|
||
|
static struct of_device_id xilinx_pci_match[] = {
|
||
|
{ .compatible = "xlnx,plbv46-pci-1.03.a", },
|
||
|
{}
|
||
|
};
|
||
|
|
||
|
/**
|
||
|
* xilinx_pci_fixup_bridge - Block Xilinx PHB configuration.
|
||
|
*/
|
||
|
static void xilinx_pci_fixup_bridge(struct pci_dev *dev)
|
||
|
{
|
||
|
struct pci_controller *hose;
|
||
|
int i;
|
||
|
|
||
|
if (dev->devfn || dev->bus->self)
|
||
|
return;
|
||
|
|
||
|
hose = pci_bus_to_host(dev->bus);
|
||
|
if (!hose)
|
||
|
return;
|
||
|
|
||
|
if (!of_match_node(xilinx_pci_match, hose->dn))
|
||
|
return;
|
||
|
|
||
|
/* Hide the PCI host BARs from the kernel as their content doesn't
|
||
|
* fit well in the resource management
|
||
|
*/
|
||
|
for (i = 0; i < DEVICE_COUNT_RESOURCE; i++) {
|
||
|
dev->resource[i].start = 0;
|
||
|
dev->resource[i].end = 0;
|
||
|
dev->resource[i].flags = 0;
|
||
|
}
|
||
|
|
||
|
dev_info(&dev->dev, "Hiding Xilinx plb-pci host bridge resources %s\n",
|
||
|
pci_name(dev));
|
||
|
}
|
||
|
DECLARE_PCI_FIXUP_HEADER(PCI_ANY_ID, PCI_ANY_ID, xilinx_pci_fixup_bridge);
|
||
|
|
||
|
/**
|
||
|
* xilinx_pci_exclude_device - Don't do config access for non-root bus
|
||
|
*
|
||
|
* This is a hack. Config access to any bus other than bus 0 does not
|
||
|
* currently work on the ML510 so we prevent it here.
|
||
|
*/
|
||
|
static int
|
||
|
xilinx_pci_exclude_device(struct pci_controller *hose, u_char bus, u8 devfn)
|
||
|
{
|
||
|
return (bus != 0);
|
||
|
}
|
||
|
|
||
|
/**
|
||
|
* xilinx_pci_init - Find and register a Xilinx PCI host bridge
|
||
|
*/
|
||
|
void __init xilinx_pci_init(void)
|
||
|
{
|
||
|
struct pci_controller *hose;
|
||
|
struct resource r;
|
||
|
void __iomem *pci_reg;
|
||
|
struct device_node *pci_node;
|
||
|
|
||
|
pci_node = of_find_matching_node(NULL, xilinx_pci_match);
|
||
|
if(!pci_node)
|
||
|
return;
|
||
|
|
||
|
if (of_address_to_resource(pci_node, 0, &r)) {
|
||
|
pr_err("xilinx-pci: cannot resolve base address\n");
|
||
|
return;
|
||
|
}
|
||
|
|
||
|
hose = pcibios_alloc_controller(pci_node);
|
||
|
if (!hose) {
|
||
|
pr_err("xilinx-pci: pcibios_alloc_controller() failed\n");
|
||
|
return;
|
||
|
}
|
||
|
|
||
|
/* Setup config space */
|
||
|
setup_indirect_pci(hose, r.start + XPLB_PCI_ADDR,
|
||
|
r.start + XPLB_PCI_DATA,
|
||
|
PPC_INDIRECT_TYPE_SET_CFG_TYPE);
|
||
|
|
||
|
/* According to the xilinx plbv46_pci documentation the soft-core starts
|
||
|
* a self-init when the bus master enable bit is set. Without this bit
|
||
|
* set the pci bus can't be scanned.
|
||
|
*/
|
||
|
early_write_config_word(hose, 0, 0, PCI_COMMAND, PCI_HOST_ENABLE_CMD);
|
||
|
|
||
|
/* Set the max latency timer to 255 */
|
||
|
early_write_config_byte(hose, 0, 0, PCI_LATENCY_TIMER, 0xff);
|
||
|
|
||
|
/* Set the max bus number to 255 */
|
||
|
pci_reg = of_iomap(pci_node, 0);
|
||
|
out_8(pci_reg + XPLB_PCI_BUS, 0xff);
|
||
|
iounmap(pci_reg);
|
||
|
|
||
|
/* Nothing past the root bridge is working right now. By default
|
||
|
* exclude config access to anything except bus 0 */
|
||
|
if (!ppc_md.pci_exclude_device)
|
||
|
ppc_md.pci_exclude_device = xilinx_pci_exclude_device;
|
||
|
|
||
|
/* Register the host bridge with the linux kernel! */
|
||
|
pci_process_bridge_OF_ranges(hose, pci_node, 1);
|
||
|
|
||
|
pr_info("xilinx-pci: Registered PCI host bridge\n");
|
||
|
}
|