165 lines
4.2 KiB
C
165 lines
4.2 KiB
C
/*
|
|
* linux/arch/arm/mach-nomadik/timer.c
|
|
*
|
|
* Copyright (C) 2008 STMicroelectronics
|
|
* Copyright (C) 2009 Alessandro Rubini, somewhat based on at91sam926x
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2, as
|
|
* published by the Free Software Foundation.
|
|
*/
|
|
#include <linux/init.h>
|
|
#include <linux/interrupt.h>
|
|
#include <linux/irq.h>
|
|
#include <linux/io.h>
|
|
#include <linux/clockchips.h>
|
|
#include <linux/jiffies.h>
|
|
#include <asm/mach/time.h>
|
|
#include <mach/mtu.h>
|
|
|
|
#define TIMER_CTRL 0x80 /* No divisor */
|
|
#define TIMER_PERIODIC 0x40
|
|
#define TIMER_SZ32BIT 0x02
|
|
|
|
/* Initial value for SRC control register: all timers use MXTAL/8 source */
|
|
#define SRC_CR_INIT_MASK 0x00007fff
|
|
#define SRC_CR_INIT_VAL 0x2aaa8000
|
|
|
|
static u32 nmdk_count; /* accumulated count */
|
|
static u32 nmdk_cycle; /* write-once */
|
|
static __iomem void *mtu_base;
|
|
|
|
/*
|
|
* clocksource: the MTU device is a decrementing counters, so we negate
|
|
* the value being read.
|
|
*/
|
|
static cycle_t nmdk_read_timer(struct clocksource *cs)
|
|
{
|
|
u32 count = readl(mtu_base + MTU_VAL(0));
|
|
return nmdk_count + nmdk_cycle - count;
|
|
|
|
}
|
|
|
|
static struct clocksource nmdk_clksrc = {
|
|
.name = "mtu_0",
|
|
.rating = 120,
|
|
.read = nmdk_read_timer,
|
|
.shift = 20,
|
|
.flags = CLOCK_SOURCE_IS_CONTINUOUS,
|
|
};
|
|
|
|
/*
|
|
* Clockevent device: currently only periodic mode is supported
|
|
*/
|
|
static void nmdk_clkevt_mode(enum clock_event_mode mode,
|
|
struct clock_event_device *dev)
|
|
{
|
|
unsigned long flags;
|
|
|
|
switch (mode) {
|
|
case CLOCK_EVT_MODE_PERIODIC:
|
|
/* enable interrupts -- and count current value? */
|
|
raw_local_irq_save(flags);
|
|
writel(readl(mtu_base + MTU_IMSC) | 1, mtu_base + MTU_IMSC);
|
|
raw_local_irq_restore(flags);
|
|
break;
|
|
case CLOCK_EVT_MODE_ONESHOT:
|
|
BUG(); /* Not supported, yet */
|
|
/* FALLTHROUGH */
|
|
case CLOCK_EVT_MODE_SHUTDOWN:
|
|
case CLOCK_EVT_MODE_UNUSED:
|
|
/* disable irq */
|
|
raw_local_irq_save(flags);
|
|
writel(readl(mtu_base + MTU_IMSC) & ~1, mtu_base + MTU_IMSC);
|
|
raw_local_irq_restore(flags);
|
|
break;
|
|
case CLOCK_EVT_MODE_RESUME:
|
|
break;
|
|
}
|
|
}
|
|
|
|
static struct clock_event_device nmdk_clkevt = {
|
|
.name = "mtu_0",
|
|
.features = CLOCK_EVT_FEAT_PERIODIC,
|
|
.shift = 32,
|
|
.rating = 100,
|
|
.set_mode = nmdk_clkevt_mode,
|
|
};
|
|
|
|
/*
|
|
* IRQ Handler for the timer 0 of the MTU block. The irq is not shared
|
|
* as we are the only users of mtu0 by now.
|
|
*/
|
|
static irqreturn_t nmdk_timer_interrupt(int irq, void *dev_id)
|
|
{
|
|
/* ack: "interrupt clear register" */
|
|
writel( 1 << 0, mtu_base + MTU_ICR);
|
|
|
|
/* we can't count lost ticks, unfortunately */
|
|
nmdk_count += nmdk_cycle;
|
|
nmdk_clkevt.event_handler(&nmdk_clkevt);
|
|
|
|
return IRQ_HANDLED;
|
|
}
|
|
|
|
/*
|
|
* Set up timer interrupt, and return the current time in seconds.
|
|
*/
|
|
static struct irqaction nmdk_timer_irq = {
|
|
.name = "Nomadik Timer Tick",
|
|
.flags = IRQF_DISABLED | IRQF_TIMER,
|
|
.handler = nmdk_timer_interrupt,
|
|
};
|
|
|
|
static void nmdk_timer_reset(void)
|
|
{
|
|
u32 cr;
|
|
|
|
writel(0, mtu_base + MTU_CR(0)); /* off */
|
|
|
|
/* configure load and background-load, and fire it up */
|
|
writel(nmdk_cycle, mtu_base + MTU_LR(0));
|
|
writel(nmdk_cycle, mtu_base + MTU_BGLR(0));
|
|
cr = MTU_CRn_PERIODIC | MTU_CRn_PRESCALE_1 | MTU_CRn_32BITS;
|
|
writel(cr, mtu_base + MTU_CR(0));
|
|
writel(cr | MTU_CRn_ENA, mtu_base + MTU_CR(0));
|
|
}
|
|
|
|
static void __init nmdk_timer_init(void)
|
|
{
|
|
u32 src_cr;
|
|
unsigned long rate;
|
|
int bits;
|
|
|
|
rate = CLOCK_TICK_RATE; /* 2.4MHz */
|
|
nmdk_cycle = (rate + HZ/2) / HZ;
|
|
|
|
/* Configure timer sources in "system reset controller" ctrl reg */
|
|
src_cr = readl(io_p2v(NOMADIK_SRC_BASE));
|
|
src_cr &= SRC_CR_INIT_MASK;
|
|
src_cr |= SRC_CR_INIT_VAL;
|
|
writel(src_cr, io_p2v(NOMADIK_SRC_BASE));
|
|
|
|
/* Save global pointer to mtu, used by functions above */
|
|
mtu_base = io_p2v(NOMADIK_MTU0_BASE);
|
|
|
|
/* Init the timer and register clocksource */
|
|
nmdk_timer_reset();
|
|
|
|
nmdk_clksrc.mult = clocksource_hz2mult(rate, nmdk_clksrc.shift);
|
|
bits = 8*sizeof(nmdk_count);
|
|
nmdk_clksrc.mask = CLOCKSOURCE_MASK(bits);
|
|
|
|
clocksource_register(&nmdk_clksrc);
|
|
|
|
/* Register irq and clockevents */
|
|
setup_irq(IRQ_MTU0, &nmdk_timer_irq);
|
|
nmdk_clkevt.mult = div_sc(rate, NSEC_PER_SEC, nmdk_clkevt.shift);
|
|
nmdk_clkevt.cpumask = cpumask_of(0);
|
|
clockevents_register_device(&nmdk_clkevt);
|
|
}
|
|
|
|
struct sys_timer nomadik_timer = {
|
|
.init = nmdk_timer_init,
|
|
};
|