22 lines
841 B
Plaintext
22 lines
841 B
Plaintext
A problem with the original firmware and satip-axe firmware is that
|
|
sometimes there are many continuity errors in the stream. Also, sometimes
|
|
the 8192 PID (means FULLMUX) does not work (bandwidth only few KB instead
|
|
megabytes).
|
|
|
|
The CC errors are visible using 'axe-debug pti vdev 0' or
|
|
'grep -v AAAAAAAAAAAA /proc/STAPI/stpti/PTI0/vDeviceInfo'.
|
|
The CC errors are not detected by the PTI interface when 8192 PID (fullmux)
|
|
is used.
|
|
|
|
So there is a data-loss somewhere between STV0900 (demux) and STx7018 (PTI).
|
|
|
|
The data-loss is visible more when multiple tuners are used together.
|
|
|
|
Possible steps:
|
|
|
|
- decode I2C communication with the demodulator
|
|
- try to inject I2C commands to STV0900
|
|
- write own axe-fe module ? because nothing else depends on it,
|
|
it could be replaced, the only big thing is to determine the i2c
|
|
connection to STx7018
|