Kernel driver smsc47b397
 | 
						|
========================
 | 
						|
 | 
						|
Supported chips:
 | 
						|
  * SMSC LPC47B397-NC
 | 
						|
  * SMSC SCH5307-NS
 | 
						|
  * SMSC SCH5317
 | 
						|
    Prefix: 'smsc47b397'
 | 
						|
    Addresses scanned: none, address read from Super I/O config space
 | 
						|
    Datasheet: In this file
 | 
						|
 | 
						|
Authors: Mark M. Hoffman <mhoffman@lightlink.com>
 | 
						|
         Utilitek Systems, Inc.
 | 
						|
 | 
						|
November 23, 2004
 | 
						|
 | 
						|
The following specification describes the SMSC LPC47B397-NC[1] sensor chip
 | 
						|
(for which there is no public datasheet available). This document was
 | 
						|
provided by Craig Kelly (In-Store Broadcast Network) and edited/corrected
 | 
						|
by Mark M. Hoffman <mhoffman@lightlink.com>.
 | 
						|
 | 
						|
[1] And SMSC SCH5307-NS and SCH5317, which have different device IDs but are
 | 
						|
otherwise compatible.
 | 
						|
 | 
						|
* * * * *
 | 
						|
 | 
						|
Methods for detecting the HP SIO and reading the thermal data on a dc7100.
 | 
						|
 | 
						|
The thermal information on the dc7100 is contained in the SIO Hardware Monitor
 | 
						|
(HWM). The information is accessed through an index/data pair. The index/data
 | 
						|
pair is located at the HWM Base Address + 0 and the HWM Base Address + 1. The
 | 
						|
HWM Base address can be obtained from Logical Device 8, registers 0x60 (MSB)
 | 
						|
and 0x61 (LSB). Currently we are using 0x480 for the HWM Base Address and
 | 
						|
0x480 and 0x481 for the index/data pair.
 | 
						|
 | 
						|
Reading temperature information.
 | 
						|
The temperature information is located in the following registers:
 | 
						|
Temp1		0x25	(Currently, this reflects the CPU temp on all systems).
 | 
						|
Temp2		0x26
 | 
						|
Temp3		0x27
 | 
						|
Temp4		0x80
 | 
						|
 | 
						|
Programming Example
 | 
						|
The following is an example of how to read the HWM temperature registers:
 | 
						|
MOV	DX,480H
 | 
						|
MOV	AX,25H
 | 
						|
OUT	DX,AL
 | 
						|
MOV	DX,481H
 | 
						|
IN	AL,DX
 | 
						|
 | 
						|
AL contains the data in hex, the temperature in Celsius is the decimal
 | 
						|
equivalent.
 | 
						|
 | 
						|
Ex: If AL contains 0x2A, the temperature is 42 degrees C.
 | 
						|
 | 
						|
Reading tach information.
 | 
						|
The fan speed information is located in the following registers:
 | 
						|
		LSB	MSB
 | 
						|
Tach1		0x28	0x29	(Currently, this reflects the CPU
 | 
						|
				fan speed on all systems).
 | 
						|
Tach2		0x2A	0x2B
 | 
						|
Tach3		0x2C	0x2D
 | 
						|
Tach4		0x2E	0x2F
 | 
						|
 | 
						|
Important!!!
 | 
						|
Reading the tach LSB locks the tach MSB.
 | 
						|
The LSB Must be read first.
 | 
						|
 | 
						|
How to convert the tach reading to RPM.
 | 
						|
The tach reading (TCount) is given by: (Tach MSB * 256) + (Tach LSB)
 | 
						|
The SIO counts the number of 90kHz (11.111us) pulses per revolution.
 | 
						|
RPM = 60/(TCount * 11.111us)
 | 
						|
 | 
						|
Example:
 | 
						|
Reg 0x28 = 0x9B
 | 
						|
Reg 0x29 = 0x08
 | 
						|
 | 
						|
TCount = 0x89B = 2203
 | 
						|
 | 
						|
RPM = 60 / (2203 * 11.11111 E-6) = 2451 RPM
 | 
						|
 | 
						|
Obtaining the SIO version.
 | 
						|
 | 
						|
CONFIGURATION SEQUENCE
 | 
						|
To program the configuration registers, the following sequence must be followed:
 | 
						|
1. Enter Configuration Mode
 | 
						|
2. Configure the Configuration Registers
 | 
						|
3. Exit Configuration Mode.
 | 
						|
 | 
						|
Enter Configuration Mode
 | 
						|
To place the chip into the Configuration State The config key (0x55) is written
 | 
						|
to the CONFIG PORT (0x2E).
 | 
						|
 | 
						|
Configuration Mode
 | 
						|
In configuration mode, the INDEX PORT is located at the CONFIG PORT address and
 | 
						|
the DATA PORT is at INDEX PORT address + 1.
 | 
						|
 | 
						|
The desired configuration registers are accessed in two steps:
 | 
						|
a.	Write the index of the Logical Device Number Configuration Register
 | 
						|
	(i.e., 0x07) to the INDEX PORT and then write the number of the
 | 
						|
	desired logical device to the DATA PORT.
 | 
						|
 | 
						|
b.	Write the address of the desired configuration register within the
 | 
						|
	logical device to the INDEX PORT and then write or read the config-
 | 
						|
	uration register through the DATA PORT.
 | 
						|
 | 
						|
Note: If accessing the Global Configuration Registers, step (a) is not required.
 | 
						|
 | 
						|
Exit Configuration Mode
 | 
						|
To exit the Configuration State the write 0xAA to the CONFIG PORT (0x2E).
 | 
						|
The chip returns to the RUN State.  (This is important).
 | 
						|
 | 
						|
Programming Example
 | 
						|
The following is an example of how to read the SIO Device ID located at 0x20
 | 
						|
 | 
						|
; ENTER CONFIGURATION MODE
 | 
						|
MOV	DX,02EH
 | 
						|
MOV	AX,055H
 | 
						|
OUT	DX,AL
 | 
						|
; GLOBAL CONFIGURATION  REGISTER
 | 
						|
MOV	DX,02EH
 | 
						|
MOV	AL,20H
 | 
						|
OUT	DX,AL
 | 
						|
; READ THE DATA
 | 
						|
MOV	DX,02FH
 | 
						|
IN	AL,DX
 | 
						|
; EXIT CONFIGURATION MODE
 | 
						|
MOV	DX,02EH
 | 
						|
MOV	AX,0AAH
 | 
						|
OUT	DX,AL
 | 
						|
 | 
						|
The registers of interest for identifying the SIO on the dc7100 are Device ID
 | 
						|
(0x20) and Device Rev  (0x21).
 | 
						|
 | 
						|
The Device ID will read 0x6F (0x81 for SCH5307-NS, and 0x85 for SCH5317)
 | 
						|
The Device Rev currently reads 0x01
 | 
						|
 | 
						|
Obtaining the HWM Base Address.
 | 
						|
The following is an example of how to read the HWM Base Address located in
 | 
						|
Logical Device 8.
 | 
						|
 | 
						|
; ENTER CONFIGURATION MODE
 | 
						|
MOV	DX,02EH
 | 
						|
MOV	AX,055H
 | 
						|
OUT	DX,AL
 | 
						|
; CONFIGURE REGISTER CRE0,
 | 
						|
; LOGICAL DEVICE 8
 | 
						|
MOV	DX,02EH
 | 
						|
MOV	AL,07H
 | 
						|
OUT	DX,AL ;Point to LD# Config Reg
 | 
						|
MOV	DX,02FH
 | 
						|
MOV	AL, 08H
 | 
						|
OUT	DX,AL;Point to Logical Device 8
 | 
						|
;
 | 
						|
MOV	DX,02EH
 | 
						|
MOV	AL,60H
 | 
						|
OUT	DX,AL	; Point to HWM Base Addr MSB
 | 
						|
MOV	DX,02FH
 | 
						|
IN	AL,DX	; Get MSB of HWM Base Addr
 | 
						|
; EXIT CONFIGURATION MODE
 | 
						|
MOV	DX,02EH
 | 
						|
MOV	AX,0AAH
 | 
						|
OUT	DX,AL
 |