Kernel driver adm1026
 | 
						|
=====================
 | 
						|
 | 
						|
Supported chips:
 | 
						|
  * Analog Devices ADM1026
 | 
						|
    Prefix: 'adm1026'
 | 
						|
    Addresses scanned: I2C 0x2c, 0x2d, 0x2e
 | 
						|
    Datasheet: Publicly available at the Analog Devices website
 | 
						|
               http://www.analog.com/en/prod/0,,766_825_ADM1026,00.html
 | 
						|
 | 
						|
Authors:
 | 
						|
        Philip Pokorny <ppokorny@penguincomputing.com> for Penguin Computing
 | 
						|
        Justin Thiessen <jthiessen@penguincomputing.com>
 | 
						|
 | 
						|
Module Parameters
 | 
						|
-----------------
 | 
						|
 | 
						|
* gpio_input: int array (min = 1, max = 17)
 | 
						|
  List of GPIO pins (0-16) to program as inputs
 | 
						|
* gpio_output: int array (min = 1, max = 17)
 | 
						|
  List of GPIO pins (0-16) to program as outputs
 | 
						|
* gpio_inverted: int array (min = 1, max = 17)
 | 
						|
  List of GPIO pins (0-16) to program as inverted
 | 
						|
* gpio_normal: int array (min = 1, max = 17)
 | 
						|
  List of GPIO pins (0-16) to program as normal/non-inverted
 | 
						|
* gpio_fan: int array (min = 1, max = 8)
 | 
						|
  List of GPIO pins (0-7) to program as fan tachs
 | 
						|
 | 
						|
 | 
						|
Description
 | 
						|
-----------
 | 
						|
 | 
						|
This driver implements support for the Analog Devices ADM1026. Analog
 | 
						|
Devices calls it a "complete thermal system management controller."
 | 
						|
 | 
						|
The ADM1026 implements three (3) temperature sensors, 17 voltage sensors,
 | 
						|
16 general purpose digital I/O lines, eight (8) fan speed sensors (8-bit),
 | 
						|
an analog output and a PWM output along with limit, alarm and mask bits for
 | 
						|
all of the above. There is even 8k bytes of EEPROM memory on chip.
 | 
						|
 | 
						|
Temperatures are measured in degrees Celsius. There are two external
 | 
						|
sensor inputs and one internal sensor. Each sensor has a high and low
 | 
						|
limit. If the limit is exceeded, an interrupt (#SMBALERT) can be
 | 
						|
generated. The interrupts can be masked. In addition, there are over-temp
 | 
						|
limits for each sensor. If this limit is exceeded, the #THERM output will
 | 
						|
be asserted. The current temperature and limits have a resolution of 1
 | 
						|
degree.
 | 
						|
 | 
						|
Fan rotation speeds are reported in RPM (rotations per minute) but measured
 | 
						|
in counts of a 22.5kHz internal clock. Each fan has a high limit which
 | 
						|
corresponds to a minimum fan speed. If the limit is exceeded, an interrupt
 | 
						|
can be generated. Each fan can be programmed to divide the reference clock
 | 
						|
by 1, 2, 4 or 8. Not all RPM values can accurately be represented, so some
 | 
						|
rounding is done. With a divider of 8, the slowest measurable speed of a
 | 
						|
two pulse per revolution fan is 661 RPM.
 | 
						|
 | 
						|
There are 17 voltage sensors. An alarm is triggered if the voltage has
 | 
						|
crossed a programmable minimum or maximum limit. Note that minimum in this
 | 
						|
case always means 'closest to zero'; this is important for negative voltage
 | 
						|
measurements. Several inputs have integrated attenuators so they can measure
 | 
						|
higher voltages directly. 3.3V, 5V, 12V, -12V and battery voltage all have
 | 
						|
dedicated inputs. There are several inputs scaled to 0-3V full-scale range
 | 
						|
for SCSI terminator power. The remaining inputs are not scaled and have
 | 
						|
a 0-2.5V full-scale range. A 2.5V or 1.82V reference voltage is provided
 | 
						|
for negative voltage measurements.
 | 
						|
 | 
						|
If an alarm triggers, it will remain triggered until the hardware register
 | 
						|
is read at least once. This means that the cause for the alarm may already
 | 
						|
have disappeared! Note that in the current implementation, all hardware
 | 
						|
registers are read whenever any data is read (unless it is less than 2.0
 | 
						|
seconds since the last update). This means that you can easily miss
 | 
						|
once-only alarms.
 | 
						|
 | 
						|
The ADM1026 measures continuously. Analog inputs are measured about 4
 | 
						|
times a second. Fan speed measurement time depends on fan speed and
 | 
						|
divisor. It can take as long as 1.5 seconds to measure all fan speeds.
 | 
						|
 | 
						|
The ADM1026 has the ability to automatically control fan speed based on the
 | 
						|
temperature sensor inputs. Both the PWM output and the DAC output can be
 | 
						|
used to control fan speed. Usually only one of these two outputs will be
 | 
						|
used. Write the minimum PWM or DAC value to the appropriate control
 | 
						|
register. Then set the low temperature limit in the tmin values for each
 | 
						|
temperature sensor. The range of control is fixed at 20 °C, and the
 | 
						|
largest difference between current and tmin of the temperature sensors sets
 | 
						|
the control output. See the datasheet for several example circuits for
 | 
						|
controlling fan speed with the PWM and DAC outputs. The fan speed sensors
 | 
						|
do not have PWM compensation, so it is probably best to control the fan
 | 
						|
voltage from the power lead rather than on the ground lead.
 | 
						|
 | 
						|
The datasheet shows an example application with VID signals attached to
 | 
						|
GPIO lines. Unfortunately, the chip may not be connected to the VID lines
 | 
						|
in this way. The driver assumes that the chips *is* connected this way to
 | 
						|
get a VID voltage.
 |