Kernel driver f71882fg
 | 
						|
======================
 | 
						|
 | 
						|
Supported chips:
 | 
						|
  * Fintek F71858FG
 | 
						|
    Prefix: 'f71858fg'
 | 
						|
    Addresses scanned: none, address read from Super I/O config space
 | 
						|
    Datasheet: Available from the Fintek website
 | 
						|
  * Fintek F71862FG and F71863FG
 | 
						|
    Prefix: 'f71862fg'
 | 
						|
    Addresses scanned: none, address read from Super I/O config space
 | 
						|
    Datasheet: Available from the Fintek website
 | 
						|
  * Fintek F71882FG and F71883FG
 | 
						|
    Prefix: 'f71882fg'
 | 
						|
    Addresses scanned: none, address read from Super I/O config space
 | 
						|
    Datasheet: Available from the Fintek website
 | 
						|
  * Fintek F8000
 | 
						|
    Prefix: 'f8000'
 | 
						|
    Addresses scanned: none, address read from Super I/O config space
 | 
						|
    Datasheet: Not public
 | 
						|
 | 
						|
Author: Hans de Goede <hdegoede@redhat.com>
 | 
						|
 | 
						|
 | 
						|
Description
 | 
						|
-----------
 | 
						|
 | 
						|
Fintek F718xxFG/F8000 Super I/O chips include complete hardware monitoring
 | 
						|
capabilities. They can monitor up to 9 voltages (3 for the F8000), 4 fans and
 | 
						|
3 temperature sensors.
 | 
						|
 | 
						|
These chips also have fan controlling features, using either DC or PWM, in
 | 
						|
three different modes (one manual, two automatic).
 | 
						|
 | 
						|
The driver assumes that no more than one chip is present, which seems
 | 
						|
reasonable.
 | 
						|
 | 
						|
 | 
						|
Monitoring
 | 
						|
----------
 | 
						|
 | 
						|
The Voltage, Fan and Temperature Monitoring uses the standard sysfs
 | 
						|
interface as documented in sysfs-interface, without any exceptions.
 | 
						|
 | 
						|
 | 
						|
Fan Control
 | 
						|
-----------
 | 
						|
 | 
						|
Both PWM (pulse-width modulation) and DC fan speed control methods are
 | 
						|
supported. The right one to use depends on external circuitry on the
 | 
						|
motherboard, so the driver assumes that the BIOS set the method
 | 
						|
properly.
 | 
						|
 | 
						|
There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC
 | 
						|
voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM
 | 
						|
mode where the actual RPM of the fan (as measured) is controlled and the speed
 | 
						|
gets specified as 0-100% of the fan#_full_speed file.
 | 
						|
 | 
						|
Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a
 | 
						|
whole lot of a difference when modifying fan control settings. The only
 | 
						|
important difference is that in RPM mode the 0-100% controls the fan speed
 | 
						|
between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs
 | 
						|
RPM mode, it will also set fan#_full_speed properly, if it does not then
 | 
						|
fan control will not work properly, unless you set a sane fan#_full_speed
 | 
						|
value yourself.
 | 
						|
 | 
						|
Switching between these modes requires re-initializing a whole bunch of
 | 
						|
registers, so the mode which the BIOS has set is kept. The mode is
 | 
						|
printed when loading the driver.
 | 
						|
 | 
						|
Three different fan control modes are supported; the mode number is written
 | 
						|
to the pwm#_enable file. Note that not all modes are supported on all
 | 
						|
chips, and some modes may only be available in RPM / PWM mode.
 | 
						|
Writing an unsupported mode will result in an invalid parameter error.
 | 
						|
 | 
						|
* 1: Manual mode
 | 
						|
  You ask for a specific PWM duty cycle / DC voltage or a specific % of
 | 
						|
  fan#_full_speed by writing to the pwm# file. This mode is only
 | 
						|
  available on the F71858FG / F8000 if the fan channel is in RPM mode.
 | 
						|
 | 
						|
* 2: Normal auto mode
 | 
						|
  You can define a number of temperature/fan speed trip points, which % the
 | 
						|
  fan should run at at this temp and which temp a fan should follow using the
 | 
						|
  standard sysfs interface. The number and type of trip points is chip
 | 
						|
  depended, see which files are available in sysfs.
 | 
						|
  Fan/PWM channel 3 of the F8000 is always in this mode!
 | 
						|
 | 
						|
* 3: Thermostat mode (Only available on the F8000 when in duty cycle mode)
 | 
						|
  The fan speed is regulated to keep the temp the fan is mapped to between
 | 
						|
  temp#_auto_point2_temp and temp#_auto_point3_temp.
 | 
						|
 | 
						|
Both of the automatic modes require that pwm1 corresponds to fan1, pwm2 to
 | 
						|
fan2 and pwm3 to fan3.
 |