mirror of
https://github.com/vdr-projects/vdr.git
synced 2025-03-01 10:50:46 +00:00
Providing channel number and file name to the shutdown program
This commit is contained in:
8
INSTALL
8
INSTALL
@@ -109,7 +109,7 @@ active, the user has been inactive for at least MinUserInactivity minutes
|
||||
and the next timer event is at least MinEventTimeout minutes in the future
|
||||
(see the Setup parameters in MANUAL).
|
||||
|
||||
The command given in the '-s' option will be called with two parameters.
|
||||
The command given in the '-s' option will be called with four parameters.
|
||||
The first one is the time (in UTC) of the next timer event (as a time_t
|
||||
type number), and the second one is the number of seconds from the current
|
||||
time until the next timer event. Your program can choose which one to use
|
||||
@@ -129,6 +129,12 @@ and only perform the system shutdown. A program that uses the second parameter
|
||||
to set the hardware for restart must therefore also check whether the first
|
||||
parameter is '0'.
|
||||
|
||||
The third parameter contains the number of the channel that will be recorded
|
||||
by the next timer (or 0 if no timer is present), and the fourth parameter
|
||||
contains the file name of the recording as defined in the timer (or an empty
|
||||
string if no timer is present). These can be used by the shutdown program to
|
||||
show that information on some display interface etc.
|
||||
|
||||
If a timer is currently recording, the parameters will reflect the start
|
||||
time of that timer. This means that the first parameter will be a time in
|
||||
the past, and the second parameter will be a negative number. This only
|
||||
|
Reference in New Issue