# node-red-node-wemo
|
|
|
|
A set of Node-RED nodes for working with Belkin WeMo devices.
|
|
|
|
These nodes use the uPnP discovery so may not discover your devices if you have a firewall enabled
|
|
|
|
Install
|
|
-------
|
|
|
|
Run the following command in your Node-RED user directory - typically `~/.node-red`
|
|
|
|
npm install node-red-node-wemo
|
|
|
|
|
|
## Output node
|
|
|
|
The output node switches a socket, a light or group of lights on or off
|
|
|
|
This should be backward compatible with the pervious version of this node but will benefit
|
|
from opening the config dialog and selecting the node you want.
|
|
|
|
The node accepts the following `msg.payload` as input
|
|
|
|
* A single value
|
|
* String : `on`/`off`
|
|
* Integer : `1`/`0`
|
|
* Boolean : `true`/`false`
|
|
|
|
|
|
* A JSON Object as below (lights only and color control is still work in the progress)
|
|
|
|
```
|
|
{
|
|
state: 1,
|
|
dim: 255,
|
|
color: '255,255,255',
|
|
temperature: 25000
|
|
}
|
|
```
|
|
|
|
**Note**: Currently any invalid value is treated as an `off` command.
|
|
|
|
## Input Node
|
|
|
|
The new input node is now based on uPnP notifications instead of polling. This means messages
|
|
will only be set when an actual change occurs in on the device. This means the node will not
|
|
send regular no-change messages.
|
|
|
|
The output varies depending on the type of device but examples for sockets look like this:
|
|
|
|
```
|
|
{
|
|
"raw": "<e:propertyset xmlns:e=\"urn:schemas-upnp-org:event-1-0\">\n<e:property>\n<BinaryState>1</BinaryState>\n</e:property>\n</e:propertyset>\n\n\r",
|
|
"state": "1",
|
|
"sid": "uuid:e2c4586c-1dd1-11b2-8f61-b535035ae35d",
|
|
"type": "socket",
|
|
"name": "Bedroom Switch",
|
|
"id": "221448K1100085"
|
|
}
|
|
```
|
|
|
|
And a lightbulb can look like this:
|
|
|
|
```
|
|
{
|
|
"raw": "<e:propertyset xmlns:e=\"urn:schemas-upnp-org:event-1-0\">\n<e:property>\n<StatusChange><?xml version="1.0" encoding="utf-8"?><StateEvent><DeviceID\navailable="YES">94103EA2B27803ED</DeviceID><CapabilityId>10006</CapabilityId><Value>1</Value></StateEvent>\n</StatusChange>\n</e:property>\n</e:propertyset>\n\n\r",
|
|
"id": "94103EA2B27803ED",
|
|
"capability": "10006",
|
|
"value": "1",
|
|
"sid": "uuid:e2e5739e-1dd1-11b2-943d-c238ce2bad17",
|
|
"type": "light",
|
|
"name": "Bedroom"
|
|
}
|
|
```
|
|
|
|
An Insight socket output can look like this:
|
|
|
|
```
|
|
{
|
|
"raw": "<e:propertyset xmlns:e=\"urn:schemas-upnp-org:event-1-0\">\n<e:property>\n<BinaryState>8|1454271649|301|834|56717|1209600|8|1010|638602|12104165</BinaryState>\n</e:property>\n</e:propertyset>\n\n\r",
|
|
"state": "8",
|
|
"onSince": 1611179325,
|
|
"onFor": 2545,
|
|
"onToday": 17432,
|
|
"onTotal": 47939,
|
|
"averagePower": 13,
|
|
"power": 3.205,
|
|
"energyToday": 3596536,
|
|
"energyTotal": 9966151
|
|
"sid": "uuid:ea808ecc-1dd1-11b2-9579-8e5c117d479e",
|
|
"type": "socket",
|
|
"name": "WeMo Insight",
|
|
"id": "221450K1200F5C"
|
|
}
|
|
```
|
|
Some information about those power parameters:
|
|
+ `state`: Whether the device is currently ON or OFF (1 or 0).
|
|
+ `onSince`: The date and time when the device was last turned on or off (as a Unix timestamp).
|
|
+ `onFor`: How long the device was last ON for (seconds).
|
|
+ `onToday`: How long the device has been ON today (seconds).
|
|
+ `onTotal`: How long the device has been ON total (seconds).
|
|
+ `timespan`: Timespan over which onTotal is relevant (seconds). Typically 2 weeks except when first started up.
|
|
+ `averagePower`: Average power consumption (Watts).
|
|
+ `power`: Current power consumption (Watts).
|
|
+ `energyToday`: Energy used today (Watt-hours, or Wh).
|
|
+ `energyTotal`: Energy used in total (Wh).
|
|
+ `standbyLimit`: Minimum energy usage to register the insight as switched on ( milliwats, default 8000mW, configurable via WeMo App).
|
|
|
|
## Lookup Node
|
|
|
|